OMI MEDICAL VACUMN FILTER

 BENEFITS 

  • Filtration performance exceeds requirements of HTM2022. MV filter efficiency tested and BS3928 sodium flame test.
  • Low cost of ownership
  • Multiple port size for a given flowrate provides incresed flexibility during installation
  • Corrosion protected
  • Internally & externally epoxy coated
  • Small, compact & light weight
  • Easily removable, sterillisable drain flask
  • Quick & easy maintenance
  • Filter elements must be replaced every 6 months

 

      STANDARD REFERENCE CONDITIONS

      DESCRIPTION

Aluminium filters housing with drain flask for the processing of air used in the medical vacuum technology with a comprehensive range of medical vacuum The uniqufilters for centralized hospital vacuum plant installations as specified in the UK standard HTM2022.  

It is designed to protect these installations from liquid, solid and bacterial contamination. Liquids are collected in a transparent drain flask which can be easily removed for sterilization. 

e OMI designed ‘push-on’ filter element is to reduce maintenance time and allows the filter to be located in the most confined spaces. The MV grade filter elements incorporate a pre filter and low pressure loss filter to remove solid and bacterial contamination.


They use high efficiency borosilicate glass microfibre media to remove all dirt particles. All elements include stainless steel metalwork and are fitted with an external pre filter layer of 80 p.p.i., open cell reticulated polyester foam. These filters are a proven success and now include such features as differential pressure indicators which are a specific requirement of the HTM2022 medical gas pipeline specification. The efficiency of the installed filter elements exceeds the 0.005% penetration specified in HTM2022 for infectious disease unit, when tested in accordance with BS3928.