TZ-8104 roller lever actuator Limit Switch

 
 
单价 面议对比
询价 暂无
浏览 46
发货 AsiaChina付款后3天内
过期 长期有效
更新 2024-07-02 12:38
 

您还没有登录,请登录后查看联系方式


详细说明

TZ-8104 roller lever actuator Limit Switch

? Double-circuit type of limit switch.

? Compact new design approximately 1/3 the size of TMAZTZ vertical limit switches.

? With strong zinc cast base, and reinforced plastics outer shell, High. Structure preventing oil, water and pressure.

? Structure enables the terminal section to be fully opened for easy wiring.

? Degree of protection: IP65

? Aslo includes stainless steel roller model

 

TZ-8 Limit Switches

TZ-8 limit switch in the specific production and manufacture, the limit switch is installed in a pre-arranged part, when the control module installed on the production of molecular thermal motion components collides with the limit switch, the contact point posture of the limit switch completes the conversion of the power supply circuit. Therefore, the limit switch is a kind of household appliance that converts the power supply circuit according to the stroke arrangement part of the fitness exercise component, and its basic principle of efficacy is similar to that of the button.

 

 

Ratings

Rated voltage

Noninductive Load (A)

Inductive Load (A)

Resistance Load

Lamp Load

Inductive Load (A)

Motor Load

NC

NO

NC

NO

NC

NO

NC

NO

125VAC

5

5

1.5

0.7

3

3

2

1

250VAC

5

5

1

0.5

3

3

1.5

0.8

8VDC

5

5

3

3

5

4

3

3

14VDC

5

5

3

3

4

4

3

3

30VDC

5

5

3

3

4

4

3

3

125VDC

0.4

0.4







250VDC

0.2

0.2







Inrush Current

N.C: below  24A, N.O: below  12A

 

NOTE: 

1. Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec.max.(DC).

2. Lamp load has an inrush current of 10 times the steady-state current,while motor load has an inrush current of 6 times the steady-state current.

3. Product with spring, its usable range of operating part is within one third of the whole spring length from the front end of spring.

 

Characteristics

Operation speed

0.5mm-50cm/sec

Operating frequency

Electical: 30 operations/minute

Contact resistance

25m? max. (initial value)

Insulation resistance

100m? min. (below 500VDC)

Shock

Mechanical durable: 1, 000m/Sec2 (about 100G'S)
Malfunction: 300m/Sec2 (about 30G'S)

Ambient temperature

-5~+65? (With no icing)

Humidity

<95% RH

Weight

About 130 to 190g

Degree of protection

IP65

Electrical Life

Above 500000

 

Operating Characteristics

Operating Characteristics

 Model

TZ-8104

TZ-8107

TZ-8108

TZ-8111

TZ-8112

TZ-8122

TZ-8166

TZ-8167

TZ-8168

TZ-8169

Operating force

OF   (Max)

5.88N

5.88N

7.84N

9.8N

9.8N

9.8N

0.88N

0.88N

0.88N

0.88N

Release force

RF   (Min)

0.49N

0.69N

0.49N

2.94N

2.94N

2.94N

?

?

?

?

Pre-travel

PT   (Max)

20

20

20

1.5mm

1.5mm

1.5mm

30mm

30mm

30mm

30mm

Over-travel

OT   (Min)

75

75

75

4mm

4mm

4mm

?

?

?

?

Movement differential

MD  (Max)

10

10

10

1.2mm

1.2mm

1.2mm

?

?

?

?

Total travel

TT   (Min)

95

95

95

5.5mm

5.5mm

5.5mm

?

?

?

?

Operational position

OP

?

?

?

260.8mm



?

?

?

?

 